Smartes Wohnen — 2226 Building, Lustenau

Lustenau, Austria, Europe

Completed · Commercial · Passive Office Building (No HVAC) · Temperate · 2013

The 2226 building maintains interior temperatures between 22°C and 26°C year-round with no mechanical heating or cooling, relying entirely on body heat, solar gain, and controlled natural ventilation through a 76cm thick brick envelope. It demonstrated a replicable passive climate model for Central European commercial buildings.

Innovation highlights

  • no mechanical heating or cooling system whatsoever
  • 76cm solid brick wall as primary thermal mass and climate buffer
  • passive ventilation via window flaps controlled by CO2 sensors
  • internal heat load from occupancy and equipment provides all heating
  • concept has since been replicated in multiple buildings across Europe
Client / Developer
Dietrich Schwarz (private)
Architect
Baumschlager Eberle Architekten
Engineer
Merz Kley Partner
Type
Passive Office Building (No HVAC)

#passive building #thermal mass #no-HVAC #brick #natural ventilation #climate resilience