Design Solution · Water Management
Design Solution · Dream about it
Integrated rainwater and condensate treatment system for non-potable reuse in mid-market buildings.
OneWater Rain combines first-flush diversion, sediment filtration, and NSF/ANSI-55 UV disinfection to treat harvested rainwater and HVAC condensate for toilet flushing, cooling tower makeup, and irrigation. It addresses the gap between buildings too small for complex blackwater reclamation but seeking measurable water savings without major plumbing retrofit. The system leverages Epic Cleantec's parent-company operational track record (Salesforce Tower: 7.8M gal/yr reuse) but is itself a new November 2025 SKU with no independent third-party operational validation or published case studies.
OneWater Rain combines first-flush diversion, sediment filtration, and NSF/ANSI-55 UV disinfection to treat harvested rainwater and HVAC condensate for toilet flushing, cooling tower make-up, and irrigation — targeting the gap between buildings too small to justify full blackwater reclamation and those seeking measurable water savings without potable plumbing redesign. The parent company's Salesforce Tower installation (7.8 million gallons per year in reuse) provides genuine operational credibility at the system level, and NSF/ANSI-55 certification avoids bespoke permit negotiation for non-potable reuse. The critical caveat is that OneWater Rain is itself a November 2025 SKU with no independent third-party operational validation and no published case studies of its own — the Salesforce Tower performance is a different product at a different scale. Rainfall and cooling load variability mean water supply from this system is not dispatchable; tank sizing and demand-matching are design-critical decisions that cannot be optimised without site-specific hydrological and occupancy data. Non-potable applications only leaves the largest potable demand in commercial buildings — drinking, showers, sinks — untouched, so the water-savings case needs to be modelled honestly against total building consumption. An ongoing maintenance burden (filter changes, UV lamp cycling, microbial testing) and dedicated non-potable pipework add operational and capital cost. This is a sensible mid-market water-reuse concept with solid certification; the honest position is that it needs twelve to twenty-four months of reference sites before it can be specified with confidence on a project where long-term performance matters.
Epic Cleantec's Salesforce Tower blackwater system is independently documented and verified (USGBC case study, public reporting). OneWater Rain product page was last modified 20 May 2026 and references 'contracts in California and Texas' but provides no published deployment reports, performance data, user testimonials, or third-party certification beyond NSF/ANSI-55 (which is standard for UV disinfection, not system validation). No MEP design guides, O&M manuals, failure modes, or cost-per-gallon benchmarks found. Claims of 'reduced footprint and installation time' lack comparative evidence.
#rainwater harvesting #water reuse #non-potable water #condensate recovery #mid-market retrofit #UV disinfection #water conservation