Aeroseal / AeroBarrier — Pressurised Envelope Air-Sealing

Design Solution · HVAC & Energy

Design Solution · Dream about it

Pressurised aerosol envelope sealing system for air infiltration in buildings.

Aeroseal pressurises a building and injects a waterborne acrylic aerosol into the air stream to seal uncontrolled air leaks up to 5/8 inch. It addresses envelope air infiltration, which accounts for 25–40% of heating/cooling energy loss in typical buildings. Results are verified by blower-door testing post-deployment.

AeroBarrier pressurises a building and fogs a waterborne acrylic aerosol through it; the sealant deposits precisely where air is escaping, closing leaks up to 5/8 inch in cavities and junctions no trade can reach — with a blower-door test before and after putting a verified number on the result. That measured-outcome quality is rare in envelope work and is why 250,000+ buildings and national builders like Beazer have adopted it, mostly in new residential where the building is empty at the right construction stage. The target is worth the attention: infiltration accounts for 25–40% of heating and cooling loss in typical stock. The boundaries: the building must be vacated and prepped, which mostly rules out occupied retrofits; it seals what exists at application and does nothing for leakage that later develops through settlement or thermal cycling; and larger defects still need conventional remediation. Long-term adhesion under thermal cycling and the aerosol's interaction with ducts and cavities over decades are the open questions, and occupant-exposure protocols during application deserve scrutiny. Strongest as a scheduled step in new-build airtightness compliance; weakest as a fix for an occupied, leaky existing building.

Strengths

Considerations

Risks

Performance

Reality check

Strong corroboration: 250k+ buildings, major homebuilder adoption, credible venture backing (Breakthrough Energy, Climate Investment), published EPD, and peer-reviewed DOE research on airtightness impact. Blower-door verification removes subjectivity versus manual sealing. Energy reduction claims (~30%) align with DOE infiltration baseline (25–40% loss). No evidence of safety incidents or regulatory barriers in sourced materials. Limitation: source URL confirms funding fact only; full technical durability and failure-mode data not independently audited in provided excerpt.

#air_sealing #envelope_performance #energy_efficiency #blower_door_verified #retrofit #new_construction